Robertshaw® 710-509 Unitrol Gas Valve 710 Series 7000MVRLC-LP Right Valve® Equivalent

$99.00

Product Details

Right Valve® manufactured direct replacement gas valve for Robertshaw® 710-509 Unitrol 710 series low capacity gas heating valve. This gas valve from Right Valve® is a direct replacement for Robertshaw® Unitrol 7000MVRLC-LP low capacity(LC) models. The cost effective and compact size of the Right Valve® EP970-A052 gas valve is equivalent to the Robertshaw® 710-509 Unitrol low capacity(LC), manual, millivolt gas valve. Assistance offered by engineers and operators allows the gas valve to be upgraded for other various applications. It’s benefits include optional inlet/outlet size and being multi-positional enables use for many places with limited space such as patio heaters, gas logs, fireplaces, heaters, Fire Pits, fireplace log control, furnaces, commercial cooking, wall heaters, pool heaters, boilers, infrared heaters, fryers, commercial water heaters, and other low-capacity applications. The control can be mounted in any position except upside down and all models have 3-position outlets. All models include an automatic pilot safety valve, pilot outlet, manual valve(gas cock), pilot gas filter, and a pilot adjusting key. All gas valve installations and conversions must be performed by a licensed professional.

Features and Benefits

• Low Capacity(LC) Compact Size
• Outlet Screen
• Pressure Taps for Checking Inlet and Outlet Gas Pressure(Optional)
• Convenient 1/4” and 3/16” Spade Connectors to Prevent Mis-Wiring
• Multi-Positional Mounting. Any Angle Between 0° and 90° From Upright Position
• Pilot Gas Filters
• Field Upgradable
• Pilot Capacity 2CFH

Important Millivolt Wiring Information

  • Major changes to the terminals on millivolt valves were made in 1996.
  • 1000 BTU/Cu. Ft. 0.64 Specific Gravity Natural Gas @ 1″ WC pressure drop.

NOTE: Conversion Kits, Pressure Regulators, and Regulator Cover Plates

  • Use EP1751-003 to convert to Natural Gas 3.5“ W.C.
  • Use EP1751-005 to convert to Natural Gas Hi-Low Adjustable Output 1.7~3.5“ W.C.
  • Use EP1751-007 to convert to Unregulated/Non Regulated
  • Use EP1751-013 to convert to L.P. Gas/Propane 11″ W.C.
  • Use EP1751-020 to convert to L.P. Gas/Propane 10“ W.C.
  • Use EP5.5-10 to convert to L.P. Gas/Propane Hi-Low Adjustable Output 5.5~10“ W.C.
  • Use EP5.5-10.5 to convert to L.P. Gas/Propane Hi-Low Adjustable Output 5.5~10.5“ W.C.

Out of stock

Description

Specifications

Valve Type See Ordering Chart
Temperature Range (Hydraulic Models) 58° to 90°F
Pilot Outlet 1/4″ Tubing
Gas Cock Dial Marking Off-Pilot-On
Maximum Ambient Temperature 175°F
Maximum Capacity Natural Gas 70,000 BTU
Maximum Capacity L.P. Gas 112,000 BTU
Maximum Inlet Pressure 14″ W.C. (1/2 PSI)

Attribute Right Valve® Robertshaw®
Competitor Part Name/Equivalents 710-509
Factory Model/Series EP970-A052 7000MVRLC-LP

7000 MVRLC-LP

Inlet Size 3/8″ 3/8″
Pressure Regulator Setting 10.0″ L.P. Gas/Propane 10.0″ L.P. Gas/Propane
Comments Manual Model, Millivolt, Low Profile, Low Capacity Manual Model, Millivolt, Low Profile, Low Capacity
Application Patio Heaters, Gas Logs, Fireplaces, Heaters, Fire Pits, Fireplace Log Control, Furnaces, Fryers, Commercial Appliances Patio Heaters, Gas Logs, Fireplaces, Heaters, Fire Pits, Fireplace Log Control, Furnaces, Fryers, Commercial Appliances
Capillary Length N/A N/A
Description Millivolt Note: Use Two Lead Thermopiles Only Millivolt Note: Use Two Lead Thermopiles Only
Outlet Size 3/8″ Outlets(3) 3/8″ Outlets(3)
Reducer Bushing (NPT) None None

Robertshaw® 710-509 Equivalents

Manufacturer Name Part Number Repl. Type Notes
COUNTRY STOVE 760717457 Functional
COUNTRY STOVE 760717457 Functional
DEXEN 6003 Functional
EMPIRE COMFORT SYS. 746717482 Functional
EMPIRE COMFORT SYS. R3319 Functional
ENGLANDS STOVE WORKS GU-4LCNG Functional
FIREPLACE MANUFAC 711817447 Functional
HEAT-N-GLO 40-50102 Functional
HEAT-N-GLO 40-501A01 Functional
HEAT-N-GLO 762817474 Functional
HEAT-N-GLO 784827308 Functional
HEAT-N-GLO 786827310 Functional
HEATILATOR 25811 Functional
HEATILATOR 711717447 Functional
HEATILATOR 715817442 Functional
HEATILATOR 762717473 Functional
HEATILATOR 762817473 Functional
HEATILATOR 769827442 Functional
HEATILATOR 769837308 Functional
HEATILATOR 769837442 Functional
MAJESTIC 711717445 Functional
PORTLAND WILLAMETTE 760817457 Functional
PORTLAND WILLAMETTE 80-0016-35-0046-00 Functional
PRECISION GAS TECHNOLOGIES 40-501A Functional
PRECISION GAS TECHNOLOGIES 768827457 Functional
PRECISION GAS TECHNOLOGIES 768827457 Functional
ROBERTSHAW 711-702-425 Exact
STAR MFG.CO. 2JY9268 Functional
SUPERIOR FIREPLACE 768837445 Functional
SUPERIOR FIREPLACE 99644 Functional
UNKNOWN 709717486 Functional
UNKNOWN 709817329 Functional
UNKNOWN 709817479 Functional
UNKNOWN 709817486 Functional
UNKNOWN 711717487 Functional
UNKNOWN 711817444 Functional
UNKNOWN 711817487 Functional
UNKNOWN 715717442 Functional
UNKNOWN 762717457 Functional
UNKNOWN 762717474 Functional
UNKNOWN 762817457 Functional
UNKNOWN 768827308 Functional
UNKNOWN 768837308 Functional
UNKNOWN 768837444 Functional
UNKNOWN 786827474 Functional
UNKNOWN 786827498 Functional
UNKNOWN 790817329 Functional
UNKNOWN 792827360 Functional
UNKNOWN 792827498 Functional
UNKNOWN 792837482 Functional
UNKNOWN 793837482 Functional
UNKNOWN 794837482 Functional
VERMONT CASTINGS 1601762 Functional
VERMONT CASTINGS 709817488 Functional
VERMONT CASTINGS 709817489 Functional
VERMONT CASTINGS 768827476 Functional
WOLF RANGE 709817482 Functional
WOLF RANGE 784827329 Functional
WOLF RANGE 786827329 Functional

Additional information

Weight 1.5 lbs
Dimensions 4.8 × 2.2 × 4 in