Robertshaw® 710-205 Unitrol Gas Valve 710 Series 7000 SRLC Right Valve® Equivalent

$129.99

***710-205 is Currently Not-Available***
The Only Difference Between 710-205 and THIS MODEL is the Capillary Length
THIS MODEL Has a 18″ Capillary Length and 710-205 Has a 36″ Capillary Length

Product Details

Right Valve® manufactured direct replacement gas valve for Robertshaw® 710-205 Unitrol 710 series Dexen® 6003H low capacity, hydraulic-snap-action, gas heating valve. This gas valve from Right Valve® is a direct replacement for Robertshaw® Unitrol 7000 SRLC low capacity(LC)models Dexen® 6003 H. The cost effective and compact size of the Right Valve® EP970-H015-205 gas valve is equivalent to the Robertshaw® 710-205 Unitrol Dexen® 6003H low capacity(LC), manual, gas valve control. Assistance offered by engineers and operators allows the gas valve to be upgraded for other various applications. It’s benefits include optional inlet/outlet size and being multi-positional enables use for many places with limited space such as patio heaters, gas logs, fireplaces, heaters, Fire Pits, fireplace log control, Coleman furnaces, Empire Furnaces, Duo-Therm furnaces, commercial cooking, wall heaters, pool heaters, boilers, infrared heaters, fryers, commercial water heaters, recreational vehicles(RV) and other low-capacity applications. The control can be mounted in any position except upside down and all models have 3-position outlets. All models include an automatic pilot safety valve, pilot outlet, manual valve(gas cock), pilot gas filter, and a pilot adjusting key. This model includes an additional 36″ capillary. All gas valve installations and conversions must be performed by a licensed professional. Replaces all obsolete TV27 General Controls gas valves. Replaces obsolete Uniline-1000. Can be used for Wall Heaters or Free Standing Furnaces to convert from Manual Operation to Thermostatically Controlled Operation. Replaces the following: V5269E 1031 V5269E1031 0630503 P32216 P322053 V5269F VS269F 700-213 700213 7000STR-4-1H 7000STR-4 NOP295300A P295300 TV27RA05 TV27RB06 TV27RB20 500419 C596C V5267F1007 V5269J1279 C5278A T5001A V5236B1178 506307 63369 66201363369 710-204 N0P295300A P322051 320-212-164 D5267E10207-2 UNITROL 110 D5267E102072 P-1074 P1074 C5281B 15266A214 D5106A 4C2-212-190 4E2-212-164 5651-6056 6-253-117 932220 P-2357 P214200 110SRCV1C TU27RA46 VR65NBN6 032043 710-351 710-351-044 713-351 713351003 739-351 739351 739-351-003 739-351-064 TV27RA46 P295300A V5150A V5150B V5267N1009 V5106A V5150A10993 TV27RB06 TV27AA03 36C06-196 7000SRLC P295100 710-205 P295100A TV27RA44 110 SRCV-1C 710205 710-205 CARL40160 CARL37525 CAR710205, Honeywell Gas Valves: V5236B1186, V5267 E 1017, V5267E1017. Williams Wall Heater Models: ANSIZ2I49A, ANS1Z2149A, ANZ2149, 30DV-3B, 1403612, 1403611, 2203611, 2203612, 3003612, 3003611, 3003612, 3509612, 1403612. GSV710205A Gas Valve **Need to light by hand**. S.I.T. Eurosit Valve Model: 0630516 Lot 4059942. Prime Heat: RMH32T, 061762 062791, 067656. Obsolete Furnace Models: GS-17260A, VR 35DMA, VR35DMA, LN6210A. Can be used to replace Obsolete free standing furnaces with the thermostat on the outside of the unit. This thermostat will be mounted on the control: DV102AME VC235TLS 109917-2 0820617 407A895 RVC-45.

Features and Benefits

• Low Capacity(LC) Compact Size
• Outlet Screen
• Pressure Taps for Checking Inlet and Outlet Gas Pressure(Optional)
• Convenient 1/4” and 3/16” Spade Connectors to Prevent Mis-Wiring
• Multi-Positional Mounting. Any Angle Between 0° and 90° From Upright Position
• Pilot Gas Filters
• Field Upgradable
• Pilot Capacity 2CFH

Important Millivolt Wiring Information

  • Major changes to the terminals on millivolt valves were made in 1996.
  • For 12 VDC applications use 24 Volt models.
  • 1000 BTU/Cu. Ft. 0.64 Specific Gravity Natural Gas @ 1″ WC pressure drop.

NOTE: Conversion Kits, Pressure Regulators, and Regulator Cover Plates

  • Use EP1751-003 to convert to Natural Gas 3.5“ W.C.
  • Use EP1751-005 to convert to Natural Gas Hi-Low Adjustable Output 1.7~3.5“ W.C.
  • Use EP1751-007 to convert to Unregulated/Non Regulated
  • Use EP1751-013 to convert to L.P. Gas/Propane 11″ W.C.
  • Use EP1751-020 to convert to L.P. Gas/Propane 10“ W.C.
  • Use EP5.5-10 to convert to L.P. Gas/Propane Hi-Low Adjustable Output 5.5~10“ W.C.
  • Use EP5.5-10.5 to convert to L.P. Gas/Propane Hi-Low Adjustable Output 5.5~10.5“ W.C.

Out of stock

Description

Specifications

Valve Type See Ordering Chart
Temperature Range (Hydraulic Models) 58° to 90°F
Pilot Outlet 1/4″ Tubing
Gas Cock Dial Marking Off-Pilot-On
Maximum Ambient Temperature 175°F
Maximum Capacity Natural Gas 70,000 BTU
Maximum Capacity L.P. Gas 112,000 BTU
Maximum Inlet Pressure 14″ W.C. (1/2 PSI)
Attribute Right Valve® Robertshaw® Dexen Industries, Inc
Competitor Part Name/Equivalents 710-205
Factory Model/Series EP970-H015-205 7000SRLC

7000 SRLC

6003H

6003H

6003-H

Inlet Size 1/2″ 1/2″ 1/2″
Pressure Regulator Setting 3.5″ Natural Gas 3.5″ Natural Gas 3.5″ Natural Gas
Capacity 70,000 BTU Natural Gas or 112,000 BTU L.P. Gas 70,000 BTU Natural Gas or 112,000 BTU L.P. Gas 70,000 BTU Natural Gas or 112,000 BTU L.P. Gas
Comments Off-Pilot-on Dial, Low Profile, Low Capacity Off-Pilot-on Dial, Low Profile, Low Capacity Off-Pilot-on Dial, Low Profile, Low Capacity
Application Wall Furnaces/Heaters Replaces ITT-General Controls TV-27, Recreational Vehicles(RV), Campers, Patio Heaters, Gas Logs, Fireplaces, Heaters, Fire Pits, Fireplace Log Control, Furnaces, Fryers, Commercial Appliances Wall Furnaces/Heaters Replaces ITT-General Controls TV-27, Recreational Vehicles(RV), Campers, Patio Heaters, Gas Logs, Fireplaces, Heaters, Fire Pits, Fireplace Log Control, Furnaces, Fryers, Commercial Appliances Wall Furnaces/Heaters Replaces ITT-General Controls TV-27, Recreational Vehicles(RV), Campers, Patio Heaters, Gas Logs, Fireplaces, Heaters, Fire Pits, Fireplace Log Control, Furnaces, Fryers, Commercial Appliances
Capillary Length 36″ 36″ 36″
Temperature Range 58° to 90°F, 175°F Max Ambient 58° to 90°F, 175°F Max Ambient 58° to 90°F, 175°F Max Ambient
Description Hydraulic-Snap-Action, Manual Model, Low Profile, Low Capacity Hydraulic-Snap-Action, Manual Model, Low Profile, Low Capacity Hydraulic-Snap-Action, Manual Model, Low Profile, Low Capacity
Outlet Size 1/2″ 1/2″ 1/2″
Reducer Bushing (NPT) (2) 1/2″ x 3/8″ (2) 1/2″ x 3/8″ (2) 1/2″ x 3/8″
Pilot 1/4″ Tubing Outlet 1/4″ Tubing Outlet 1/4″ Tubing Outlet
Maximum Inlet Pressure 14″ W.C. (1/2 PSI) 14″ W.C. (1/2 PSI) 14″ W.C. (1/2 PSI)

Robertshaw® 710-205 Dexen® 6003H Equivalents

Manufacturer Name Part Number Repl. Type Notes
DEXEN 6003 H Exact
ELSTON MFG 10-500 Functional Also requires 1751-013
ELSTON MFG 743312037 Functional
EMPIRE COMFORT SYS. 719311022 Functional
EMPIRE COMFORT SYS. 719312023 Functional Also requires 1751-013
EMPIRE COMFORT SYS. 743312070 Functional Also requires 1751-013
EMPIRE COMFORT SYS. 771312071 Functional Also requires 1751-013
EMPIRE COMFORT SYS. 932124 Functional
EMPIRE COMFORT SYS. 932218 Functional Also requires 1751-013
EMPIRE COMFORT SYS. R2701 Functional Also requires 1751-013
EMPIRE COMFORT SYS. R2703 Functional Also requires 1751-013
itt general control wall heater TV27 Functional
ITT/GENERAL CONTROL TV27RA05 Functional For gas valve applications not exceeding 70,000 BTU
ITT/GENERAL CONTROL TV27RB20 Exact
JOHNSTONE SUPPLY L37-525 Functional
LOUISVILLE TIN STOVE 70092 Functional
LOUISVILLE TIN STOVE 70093 Functional Also requires 1751-013 for LP applications.
LOUISVILLE TIN STOVE 721311020 Functional
LOUISVILLE TIN STOVE 721312021 Functional Also requires 1751-013
LOUISVILLE TIN STOVE 739351003 Functional
LOUISVILLE TIN STOVE 743311044 Functional
LOUISVILLE TIN STOVE 743312058 Functional Also requires 1751-013
LOUISVILLE TIN STOVE 743331044 Functional
LOUISVILLE TIN STOVE 757311059 Functional
LOUISVILLE TIN STOVE 757312060 Functional Also requires 1751-013
ROBERTSHAW 7000 SRLC Functional
ROBERTSHAW 7000SRLC Functional
ROBERTSHAW 710-351-044 Functional
ROBERTSHAW 713-351-003 Exact
ROBERTSHAW 739-351-003 Exact
ROBERTSHAW 743-351-025 Functional
ROBERTSHAW 743-352-058 Functional Also requires 1751-013
SUBURBAN APPLIANCE 160807 Functional Also requires 1751-013
SUBURBAN APPLIANCE 725312028 Functional Also requires 1751-013
UNI-LINE 739331003 Exact
UNI-LINE 739351064 Exact
UNI-LINE 739351064 Functional
UNKNOWN 506307 Functional
UNKNOWN 705312012 Functional Also requires 1751-013
UNKNOWN 709311036 Functional
UNKNOWN 709312037 Functional
UNKNOWN 709321003 Functional
UNKNOWN 709322034 Functional Also requires 1751-013
UNKNOWN 709332058 Functional Also requires 1751-013
UNKNOWN 710331003 Functional
UNKNOWN 710331044 Functional
UNKNOWN 710332006 Functional Also requires 1751-013
UNKNOWN 710351044 Functional
UNKNOWN 710352058 Functional Also requires 1751-013
UNKNOWN 713312006 Functional Also requires 1751-013
UNKNOWN 713331003 Functional
UNKNOWN 713331025 Functional
UNKNOWN 713332006 Functional Also requires 1751-013
UNKNOWN 713332024 Functional Also requires 1751-013
UNKNOWN 713351003 Functional
UNKNOWN 719331018 Functional
UNKNOWN 721312016 Functional Also requires 1751-013
UNKNOWN 738332086 Functional Also requires 1751-013
UNKNOWN 743312075 Functional Also requires 1751-013
UNKNOWN 743312085 Functional Also requires 1751-013
UNKNOWN 743332058 Functional Also requires 1751-013
UNKNOWN 743351025 Functional
UNKNOWN 743351044 Functional
UNKNOWN 743352058 Functional Also requires 1751-013
UNKNOWN 744331082 Functional
UNKNOWN 744332006 Functional Also requires 1751-013
UNKNOWN 744332057 Functional Also requires 1751-013
UNKNOWN 744332083 Functional Also requires 1751-013
UNKNOWN 744351025 Functional
UNKNOWN 744351044 Functional
UNKNOWN 744352062 Functional Also requires 1751-013
UNKNOWN 771312074 Functional Also requires 1751-013
UNKNOWN 78-8264 Functional
WHITE-RODGERS 36C09-210 Functional For gas valve applications not exceeding 70,000 BTU
WILLIAMS FURNACE 743311036 Functional
WILLIAMS FURNACE 743312050 Functional Also requires 1751-013
WILLIAMS FURNACE 744331079 Functional
WILLIAMS FURNACE 744332050 Functional Also requires 1751-013
WILLIAMS FURNACE 744332080 Functional Also requires 1751-013
WILLIAMS FURNACE P295101A Functional Also requires 1751-013
WILLIAMS FURNACE P295300A Functional
WILLIAMS FURNACE P295301A Functional Also requires 1751-013
WILLIAMS FURNACE P501704 Functional
WILLIAMS FURNACE P501705 Functional Also requires 1751-013

Additional information

Weight 1.5 lbs
Dimensions 4.8 × 2.2 × 4 in