Robertshaw® 710-102 Unitrol Gas Valve 710 Series 7000MRLC Right Valve® Equivalent

$118.00

Product Details

Right Valve® manufactured direct replacement gas valve for Robertshaw® 710-102 Unitrol 710 series low capacity gas heating valve. This gas valve from Right Valve® is a direct replacement for Robertshaw® Unitrol 7000MRLC low capacity(LC) models. The cost effective and compact size of the Right Valve® EP970-A015 gas valve is equivalent to the Robertshaw® 710-102 Unitrol low capacity(LC), manual, millivolt gas valve. Assistance offered by engineers and operators allows the gas valve to be upgraded for other various applications. It’s benefits include optional inlet/outlet size and being multi-positional enables use for many places with limited space such as patio heaters, gas logs, fireplaces, heaters, Fire Pits, fireplace log control, furnaces, commercial cooking, wall heaters, pool heaters, boilers, infrared heaters, fryers, commercial water heaters, and other low-capacity applications. The control can be mounted in any position except upside down and all models have 3-position outlets. All models include an automatic pilot safety valve, pilot outlet, manual valve(gas cock), pilot gas filter, and a pilot adjusting key. All gas valve installations and conversions must be performed by a licensed professional.

Features and Benefits

• Low Capacity(LC) Compact Size
• Outlet Screen
• Pressure Taps for Checking Inlet and Outlet Gas Pressure(Optional)
• Convenient 1/4” and 3/16” Spade Connectors to Prevent Mis-Wiring
• Multi-Positional Mounting. Any Angle Between 0° and 90° From Upright Position
• Pilot Gas Filters
• Field Upgradable
• Pilot Capacity 2CFH

Important Millivolt Wiring Information

  • Major changes to the terminals on millivolt valves were made in 1996.
  • For 12 VDC applications use 24 Volt models.
  • 1000 BTU/Cu. Ft. 0.64 Specific Gravity Natural Gas @ 1″ WC pressure drop.

NOTE:Conversion Kits, Pressure Regulators, and Regulator Cover Plates

  • Use EP1751-003 to convert to Natural Gas 3.5“ W.C.
  • Use EP1751-005 to convert to Natural Gas Hi-Low Adjustable Output 1.7~3.5“ W.C.
  • Use EP1751-007 to convert to Unregulated/Non Regulated
  • Use EP1751-013 to convert to L.P. Gas/Propane 11″ W.C.
  • Use EP1751-020 to convert to L.P. Gas/Propane 10“ W.C.
  • Use EP5.5-10 to convert to L.P. Gas/Propane Hi-Low Adjustable Output 5.5~10“ W.C.
  • Use EP5.5-10.5 to convert to L.P. Gas/Propane Hi-Low Adjustable Output 5.5~10.5“ W.C.

201 in stock

Name Range Discount
Quantity Discount 3 - 9 10 %
Quantity Discount 10 - 19 15 %
Quantity Discount 20 - 99 20 %

Description

Specifications

Valve Type See Ordering Chart
Temperature Range (Hydraulic Models) 58° to 90°F
Pilot Outlet 1/4″ Tubing
Gas Cock Dial Marking Off-Pilot-On
Maximum Ambient Temperature 175°F
Maximum Capacity Natural Gas 70,000 BTU
Maximum Capacity L.P. Gas 112,000 BTU
Maximum Inlet Pressure 14″ W.C. (1/2 PSI)
Attribute Right Valve® Robertshaw®
Competitor Part Name/Equivalents 710-102
Factory Model/Series EP970-A015-710-102 7000MRLC

7000 MRLC

Inlet Size 1/2″ 1/2″
Pressure Regulator Setting 3.5″ W.C. Natural Gas 3.5″ W.C. Natural Gas
Capacity 70,000 BTU Natural Gas 70,000 BTU Natural Gas
Comments Off-Pilot-on Dial, Low Profile, Low Capacity, Millivolt Off-Pilot-on Dial, Low Profile, Low Capacity, Millivolt
Application Patio Heaters, Gas Logs, Fireplaces, Heaters, Fire Pits, Fireplace Log Control, Furnaces, Fryers, Commercial Appliances Patio Heaters, Gas Logs, Fireplaces, Heaters, Fire Pits, Fireplace Log Control, Furnaces, Fryers, Commercial Appliances
Capillary Length N/A N/A
Description Manual Model, Millivolt, Low Profile, Low Capacity Manual Model, Millivolt, Low Profile, Low Capacity
Outlet Size 1/2″ 1/2″
Reducer Bushing (NPT) (2) 1/2″ x 3/8″ (2) 1/2″ x 3/8″
Pilot 1/4″ Tubing Outlet 1/4″ Tubing Outlet
Maximum Inlet Pressure 14″ W.C. (1/2 PSI) 14″ W.C. (1/2 PSI)

Robertshaw® 710-102 Equivalents

Manufacturer Name Part Number Repl. Type Notes
DEXEN 6003 Functional
EMPIRE COMFORT SYS. 701001001 Functional
EMPIRE COMFORT SYS. 732001045 Functional
EMPIRE COMFORT SYS. 757001055 Functional
FIREPLACE PRODUCTS INTL 709002048 Functional
GARLAND 709001019 Functional
GARLAND 709001019 Functional
MAJESTIC 51832 Functional
MAJESTIC 732001026 Functional
MARTIN IND. 713001026 Functional
MARTIN IND. P2377 Functional
ORRVILLE PROD. GF7502 Functional
PORTLAND WILLAMETTE 701001019 Functional
PORTLAND WILLAMETTE 701002031 Functional Also requires 1751-013
PORTLAND WILLAMETTE 80-0016-35-0040-00 Functional
PORTLAND WILLAMETTE 80-0016-35-0041-00 Functional Also requires 1751-013
ROBERTSHAW 7000MRALC Functional Original control may have slight variances.
ROBERTSHAW 7000MRCL Functional
ROBERTSHAW 7000MRLC Exact Original control may have slight variances.
ROBERTSHAW 701-001-001 Functional
ROBERTSHAW 701-001-019 Functional
ROBERTSHAW 709-001-032 Functional
ROBERTSHAW 709-001-041 Functional
ROBERTSHAW 709-001-049 Functional
ROBERTSHAW 710-001-051 Functional
ROBERTSHAW 710-107 Functional Also requires 1751-013
ROBERTSHAW 732-001-045 Functional
ROBERTSHAW 733901205 Functional Also requires 705-452
ROBERTSHAW 736-001-001 Functional
ROBERTSHAW 739-001-001 Functional
ROBERTSHAW 743-001-038 Functional
SUPERIOR FIREPLACE 991327 Functional
TEMCO FIREPLACE 709001041 Functional
TEMCO FIREPLACE 709001041 Functional
TEMCO FIREPLACE 709001041 Functional
TEMCO FIREPLACE 709001041 Functional
TEMCO FIREPLACE 709001041 Functional
TEMCO FIREPLACE 709001041 Functional
TEMCO FIREPLACE 709001041 Functional
UNI-LINE 739002051 Functional Also requires 1751-013
UNKNOWN 701001502 Functional
UNKNOWN 701002005 Functional Also requires 1751-013
UNKNOWN 701002011 Functional Also requires 1751-013
UNKNOWN 709001001 Functional
UNKNOWN 709001032 Functional
UNKNOWN 709001038 Functional
UNKNOWN 709001049 Functional
UNKNOWN 709002005 Functional Also requires 1751-013
UNKNOWN 709002011 Functional Also requires 1751-013
UNKNOWN 709002030 Functional Also requires 1751-013
UNKNOWN 709002031 Functional Also requires 1751-013
UNKNOWN 709002053 Functional Also requires 1751-013
UNKNOWN 713001039 Functional
UNKNOWN 713002011 Functional Also requires 1751-013
UNKNOWN 713002047 Functional Also requires 1751-013
UNKNOWN 716001026 Functional
UNKNOWN 732001032 Functional
UNKNOWN 732002033 Functional Also requires 1751-013
UNKNOWN 739001001 Functional
UNKNOWN 739001051 Functional
UNKNOWN 743001038 Functional
UNKNOWN 743001084 Functional
UNKNOWN 747002030 Functional Also requires 1751-013
UNKNOWN 751001049 Functional
UNKNOWN 751002005 Functional Also requires 1751-013
UNKNOWN 757002054 Functional Also requires 1751-013
UNKNOWN 90002 Functional
WOLF RANGE WS-725-15 Functional

Additional information

Weight 1.5 lbs
Dimensions 4.8 × 2.2 × 4 in